论文部分内容阅读
一、概述依据JJG443-2006《燃油加油机》检定规程进行检定。采用标准金属量器直接测量被检加油机输出油的体积,可得到加油机示值与标准金属量器测得值之差,即为加油机的示值误差。检定条件:温度在-10℃~40℃范围内,检定过程中环境温度变化不超过5℃。检定仪器:二等标准金属量器(不锈钢材质)、精密温度计(分度值为0.1℃)。
First, an overview According to JJG443-2006 “fuel tanker” test procedures for verification. The use of standard metal measuring device directly measured the output of the tanker oil volume, can be given tanker indication and the standard metal gauge measured value of the difference, that is, the tanker indication error. Test conditions: temperature in the range of -10 ℃ ~ 40 ℃, the test process does not exceed the ambient temperature change 5 ℃. Test equipment: second-class standard metal measuring device (stainless steel), precision thermometer (indexing value of 0.1 ℃).