论文部分内容阅读
摘要:随着高层建筑的迅速发展,建筑节能作为高层建筑的一项目标工程已不容忽视。CPC装饰保温板具有质轻(35 kg/m3)、导热系数极低(0.024 W/(m•K))的优点,可以被用在高层建筑外墙保温系统中。本文介绍了CPC装饰保温系统基本构造,阐述了CPC装饰保温系统的施工工艺,得出CPC装饰保温板具有較好的推广使用价值。
关键词:高层建筑,建筑节能,施工技术,
Application of CPC Decorative Insulation Board in the High-rise Building Exterior Insulation Systems
WANG Yun-bo
ABSTRACT:With the rapid development of high-rise buildings, energy-saving as a target of high-rise building project can not be ignored. CPC decorative insulation board with light (35 kg/m3), low thermal conductivity (0.024 W / (m • K)) of the advantages that can be used in external insulation systems in high-rise buildings. The basic structure of the CPC decorative insulation system is introduced in this paper. Construction technique of CPC decorative insulation system is described. In short, CPC decorative insulation board has the better use of value.
KEY WORDS:high-rise building, energy-saving, construction technique
中图分类号:[TU208.3] 文献标识码:A文章编号:
0 前言
近年来,我国的高层建筑特别是超高层建筑发展迅速,规模越来越大,建筑外形和功能越来多样化。为人们营造一种安逸、舒适的居住环境,给建筑生命力,已经成为高层建筑的建造宗旨。建筑节能作为新建建筑的一项目标或是追求自然受到人们的重视和青睐。
可是,自上世纪80年代以来,我国的建筑行业以及相关行业一直是以能源高消费的模式发展,以追求建筑工程造价低为目的,忽略对建筑节能的研究,造成建筑外墙形式单一,门窗存有过大空隙,建筑整体保温隔热、气密性差,浪费了大量的能源。为降低我国建筑的能耗损失,我国于1986年、1996年和2004年分别制定了不同的阶段性建筑节能政策,要求新设计的建筑能耗水平应在1980年~1981年当地通用设计标准能耗基础上分别节能30%、50%和65%。2010年全国新建建筑全部严格执行节能50%的设计标准[1],其中各特大城市和部分大城市率先实施节能65%的标准。从2010年起到2020年,进一步提高建筑节能标准,平均节能率要达到65%,东部地区要达到更高的标准。一些建筑的节能率要达到75%标准[2]。虽然我国的建筑节能取得了一些成绩,但从整体上来看尚处在以点带面的起步阶段,建筑每平方米消耗的标准煤仍高于欧洲发达国家水平,而且发展不平衡。我国建筑能耗之所以巨大,其根源是新建和已建建筑物的保温性差,能源浪费严重。为解决此问题,根据我国的基本国情,必须研究开发出新型的结构体系和保温材料,按照建筑节能指标的要求,设计与施工建筑外墙外保温系统和屋顶保温等。
高层建筑使用的保温材料主要分为保温板材和保温浆料,保温浆料在较高的高层建筑中使用受到限制,因此开发一种在高层建筑普遍使用的保温板材,已成为当务之急。本文以CPC装饰保温板为例,介绍了CPC装饰保温系统的基本构造,研究了高层建筑外墙外保温的施工工艺,具有较好的使用推广价值。
1 CPC装饰保温板
CPC装饰保温板是以硬泡聚氨酯高效保温材料为芯材,两面覆盖增强水泥基卷材防护层的保温板材。CPC装饰保温板性能指标见表1。CPC装饰保温板具有质轻、导热系数极低、隔音、干湿不会变形,在超低温下使用时收缩小、不脆化等优异特性。并且可钉、可锯、施工简单方便,并且可以重复循环使用。
表1CPC装饰保温板性能要求
检验项目 单位 指标
干表观密度 kg/m3 ≥ 35
抗压强度 MPa ≥ 0.40
抗折强度 MPa ≥ 0.10
吸水率 % ≤ 3.0
垂直于板面的抗拉强度 MPa ≥ 0.10
导热系数 W/(m•K) ≤ 0.024
压缩性能(变形10%) MPa ≥ 0.15
抗冻性(15次) 质量损失 % ≤ 5.0
强度损失 % ≤ 25
软化系数 — ≥ 0.80
燃烧性能等级 — 不低于B2级
2 CPC装饰保温系统的构造
CPC装饰保温系统是以装饰层、抹面层、保温层和固定材料(胶粘剂、锚固件等)构成,并且适用于安装在外墙表面,及装饰和保温两大功能为一体的非承重构造。CPC装饰保温系统基本构造见图1。
图1CPC装饰保温系统基本构造
3.CPC装饰保温系统施工技术
3.1 施工工艺流程
CPC装饰保温系统的施工工艺基本上与聚苯板的施工工艺相同,并在此基础上进行了改进和提高。是施工工艺流程更加明确,施工操作更加方便快捷,施工质量易于控制。CPC装饰保温系统施工工艺流程见图2
图2 节能改造施工工艺流程
3.2施工工艺要点
(1)基层墙面清理
基层墙体应干燥、平整、顺直、坚实。对基层表面残留的油垢、脱模剂等妨碍粘结的附着物使用相应的溶剂进行彻底清洗,对基层墙表面大于等于10 mm的凸起物和疏松、风化的部分应剔除并予以修复,填补并密实主体结构的变形缝、伸缩缝等孔洞,其垂直度和平整度应符合施工验收规范的要求;找平层与墙体粘结牢固,不得有脱层、空鼓、有害裂缝。面层不得有粉化、起皮、爆灰、泛碱等现象。
(2)涂刷胶粘剂
按配比先将水置于搅拌器中,再把成品胶粘剂干粉料直接加入水中充分搅拌均匀,达到工程需要的粘稠度,宜静置8~15min再行搅拌一次方可使用。将配制好的胶粘剂用滚刷或扫帚均匀涂刷于墙面上。胶粘剂与基层墙体须粘接牢靠,无脱层、起鼓和裂缝,胶粘剂与水泥砂浆的拉伸粘结强度在干燥状态下不得小于0.6 MPa,浸水48h后不得小于0.4 MPa。胶粘剂不宜涂刷过厚。另胶粘剂在施工时,基层表面不宜过于干燥,若过干,应在施工前隔夜浇水湿润成阴干状,含水量也不易过大,否则会降低与基层墙体的粘结力,引起发空鼓、虚贴现象。
(4)粘贴CPC装饰保温板
将胶粘剂均匀抹于待贴的保温板表面,然后对准控制线将保温板贴于墙面并按压平实。采用点框法时应在CPC保温板四周涂抹50mm宽,10mm厚的胶粘剂,并在CPC保温板下侧预留宽度为30mm的透气通道,中间部位均匀分布涂抹直径为150mm,10mm厚的圆形粘接点(布点密度根据板的规格而定),采用条粘法时应在保温板内表面均匀涂抹6~8mm厚的胶粘剂并用专用疏板刮出横条状粘结带后,在CPC保温板中间位置纵向刮出宽度为50mm的透气通道。建筑高度在60m以下时应保证粘贴面积不低于保温板面积的40%。建筑高度在60m以上时,粘贴面积应不低于保温板面积的60%。
粘贴时,水平方向应由墙角及门窗处向两侧粘贴,粘贴时应轻揉、均匀挤压,并随时用2m靠尺和托线板检查平整度和垂直度。注意清除板边溢出的胶粘剂,相邻板间侧边不得有胶粘剂。板缝應尽量拼接严密,对板间存留较大缝隙的,宜切割保温板填塞缝口或采用泡沫聚氨酯填缝剂填缝。应严格控制相邻板块高差±1.5mm。
(4)涂抹抹面胶浆,铺贴耐碱网格布
在CPC保温板表面首遍涂1~2mm抹面胶浆,然后将耐碱网格布横向铺贴并压入胶浆中,接搓方式为上皮压下皮,抹面胶浆应充分包裹网格布,要平整压实、无褶皱。首遍抹面胶浆初凝至可以触碰时再抹第二遍抹面砂浆,厚度约为1.5mm,以完全覆盖且微见网格布轮廓为宜。抹面层厚度不宜大于5mm。抹面胶浆施工间歇处应留在阴角处或CPC板块接近中间位置,以方便后续施工的搭接。间距不小于100mm。建筑首层外墙墙体及易承受碰撞部位须首先增设一层网格布,网格布之间采用对接工艺,控制抹面层整体厚度为5~7mm。
(5)锚栓加固
在粘板后(时间根据胶粘剂凝速度)、根据单项工程设计要求钻孔,孔径视锚固件直径而定,然后用橡皮锤将专用锚栓敲入孔内拧紧压平于板面并不压破水泥基卷材面层为宜。专用锚栓布置密度为:饰面为涂料时,标高在20m以下的部位可不安装锚固件:20~60m宜为4~6个/m2;60m以上的锚栓分布宜为6~8个/m2。锚固件圆盘压住CPC保温板。
4施工注意事项
(1)CPC装饰保温系统工程施工期间以及完工24小时内,基层及环境空气温度不应低于5℃。夏季应避免阳光暴晒。在5级以上大风天气和雨天不得施工。严禁雨中施工,遇雨施工或雨季施工应有可靠的防雨措施。
(2)粘贴时应按顺砌方式粘贴,竖缝逐行错缝1/2板长粘贴,阴阳角应错茬搭接,并随时用2m靠尺和托线检查平整度和垂直度,用水平尺检查水平度。粘贴门窗洞口四周CPC保温板时应用整版保温板,拼缝不得位于门窗洞口的四角处,墙面边角处粘贴保温板时最小尺寸应不低于200mm。翻包时被压和翻包长度均不得不小于100mm。门窗洞口侧边应粘贴CPC保温板并做好收头处理。
(3)涂抹抹面胶浆前必须对保温板的平整度、垂直度和阴阳角方正度,以及门窗上口和下口的边沿线的水平度、门窗洞口的侧沿线垂直度进行检查,符合要求后方可进行抹面胶浆的施工。施工时切忌多次反复揉搓,以及造成脱浆形成空鼓、裂纹。
(4)分格缝施工时,分格条应在抹灰工序时就放入,待砂浆初凝后起出,修整缝边,分两次填嵌建筑密封膏,勾缝厚度约为缝宽的1/3。
5 质量验收
CPC装饰保温系统施工质量验收包括施工过程验收和竣工验收。施工过程验收由监理工程师组织相关验收;竣工验收有建设单位项目负责人组织专家组进行验收,工程质量监督机构对此实施监督。
(1)CPC装饰保温系统在施工过程中,应对基层墙面处理、保温层厚度和密封与锚固件处理进行隐蔽工程验收。
(2)CPC装饰保温系统工程使用的胶粘剂,抹面胶浆,增强网,锚固件的材质、规格、安装间距、数量及锚固件的拉拔力符合规程及单项工程设计要求。
(3)门窗洞口、阴阳角、分隔逢、变形缝等节点的施工安装应符合《CPC硬泡聚氨酯复合板外墙外保温系统(薄抹灰)建筑构造》图集。
(4)CPC装饰保温系统工程竣工后,有建设单位委托具有相应节能检测资质的单位进行传热系统现场抽样检测,提供检测报告。
6 结论
随着高层建筑如雨后春笋般的建设,建筑节能是执行国家节约能源、保护环境的基本国策,是缓解能源紧张,解决社会经济发展与能源供应不足这对矛盾的有效措施。高层建筑外墙外保温系统作为高层建筑节能的重要手段,必须引起重视。
参考文献
[1]JGJ26-95,民用建筑节能设计标准(采暖居住建筑部分) [S].北京:中国建筑工业出版社,1996.
[2]马保国.外墙外保温技术[M].北京:化学工业出版社,1999.32-53.
作者简介:王云波,出生年月:1979年7月17日,2001年毕业于石家庄铁道学院建筑工程专业,现工作于中铁十二局集团建筑安装工程有限公司,任副经理,工程师。
注:文章内所有公式及图表请用PDF形式查看。
关键词:高层建筑,建筑节能,施工技术,
Application of CPC Decorative Insulation Board in the High-rise Building Exterior Insulation Systems
WANG Yun-bo
ABSTRACT:With the rapid development of high-rise buildings, energy-saving as a target of high-rise building project can not be ignored. CPC decorative insulation board with light (35 kg/m3), low thermal conductivity (0.024 W / (m • K)) of the advantages that can be used in external insulation systems in high-rise buildings. The basic structure of the CPC decorative insulation system is introduced in this paper. Construction technique of CPC decorative insulation system is described. In short, CPC decorative insulation board has the better use of value.
KEY WORDS:high-rise building, energy-saving, construction technique
中图分类号:[TU208.3] 文献标识码:A文章编号:
0 前言
近年来,我国的高层建筑特别是超高层建筑发展迅速,规模越来越大,建筑外形和功能越来多样化。为人们营造一种安逸、舒适的居住环境,给建筑生命力,已经成为高层建筑的建造宗旨。建筑节能作为新建建筑的一项目标或是追求自然受到人们的重视和青睐。
可是,自上世纪80年代以来,我国的建筑行业以及相关行业一直是以能源高消费的模式发展,以追求建筑工程造价低为目的,忽略对建筑节能的研究,造成建筑外墙形式单一,门窗存有过大空隙,建筑整体保温隔热、气密性差,浪费了大量的能源。为降低我国建筑的能耗损失,我国于1986年、1996年和2004年分别制定了不同的阶段性建筑节能政策,要求新设计的建筑能耗水平应在1980年~1981年当地通用设计标准能耗基础上分别节能30%、50%和65%。2010年全国新建建筑全部严格执行节能50%的设计标准[1],其中各特大城市和部分大城市率先实施节能65%的标准。从2010年起到2020年,进一步提高建筑节能标准,平均节能率要达到65%,东部地区要达到更高的标准。一些建筑的节能率要达到75%标准[2]。虽然我国的建筑节能取得了一些成绩,但从整体上来看尚处在以点带面的起步阶段,建筑每平方米消耗的标准煤仍高于欧洲发达国家水平,而且发展不平衡。我国建筑能耗之所以巨大,其根源是新建和已建建筑物的保温性差,能源浪费严重。为解决此问题,根据我国的基本国情,必须研究开发出新型的结构体系和保温材料,按照建筑节能指标的要求,设计与施工建筑外墙外保温系统和屋顶保温等。
高层建筑使用的保温材料主要分为保温板材和保温浆料,保温浆料在较高的高层建筑中使用受到限制,因此开发一种在高层建筑普遍使用的保温板材,已成为当务之急。本文以CPC装饰保温板为例,介绍了CPC装饰保温系统的基本构造,研究了高层建筑外墙外保温的施工工艺,具有较好的使用推广价值。
1 CPC装饰保温板
CPC装饰保温板是以硬泡聚氨酯高效保温材料为芯材,两面覆盖增强水泥基卷材防护层的保温板材。CPC装饰保温板性能指标见表1。CPC装饰保温板具有质轻、导热系数极低、隔音、干湿不会变形,在超低温下使用时收缩小、不脆化等优异特性。并且可钉、可锯、施工简单方便,并且可以重复循环使用。
表1CPC装饰保温板性能要求
检验项目 单位 指标
干表观密度 kg/m3 ≥ 35
抗压强度 MPa ≥ 0.40
抗折强度 MPa ≥ 0.10
吸水率 % ≤ 3.0
垂直于板面的抗拉强度 MPa ≥ 0.10
导热系数 W/(m•K) ≤ 0.024
压缩性能(变形10%) MPa ≥ 0.15
抗冻性(15次) 质量损失 % ≤ 5.0
强度损失 % ≤ 25
软化系数 — ≥ 0.80
燃烧性能等级 — 不低于B2级
2 CPC装饰保温系统的构造
CPC装饰保温系统是以装饰层、抹面层、保温层和固定材料(胶粘剂、锚固件等)构成,并且适用于安装在外墙表面,及装饰和保温两大功能为一体的非承重构造。CPC装饰保温系统基本构造见图1。
图1CPC装饰保温系统基本构造
3.CPC装饰保温系统施工技术
3.1 施工工艺流程
CPC装饰保温系统的施工工艺基本上与聚苯板的施工工艺相同,并在此基础上进行了改进和提高。是施工工艺流程更加明确,施工操作更加方便快捷,施工质量易于控制。CPC装饰保温系统施工工艺流程见图2
图2 节能改造施工工艺流程
3.2施工工艺要点
(1)基层墙面清理
基层墙体应干燥、平整、顺直、坚实。对基层表面残留的油垢、脱模剂等妨碍粘结的附着物使用相应的溶剂进行彻底清洗,对基层墙表面大于等于10 mm的凸起物和疏松、风化的部分应剔除并予以修复,填补并密实主体结构的变形缝、伸缩缝等孔洞,其垂直度和平整度应符合施工验收规范的要求;找平层与墙体粘结牢固,不得有脱层、空鼓、有害裂缝。面层不得有粉化、起皮、爆灰、泛碱等现象。
(2)涂刷胶粘剂
按配比先将水置于搅拌器中,再把成品胶粘剂干粉料直接加入水中充分搅拌均匀,达到工程需要的粘稠度,宜静置8~15min再行搅拌一次方可使用。将配制好的胶粘剂用滚刷或扫帚均匀涂刷于墙面上。胶粘剂与基层墙体须粘接牢靠,无脱层、起鼓和裂缝,胶粘剂与水泥砂浆的拉伸粘结强度在干燥状态下不得小于0.6 MPa,浸水48h后不得小于0.4 MPa。胶粘剂不宜涂刷过厚。另胶粘剂在施工时,基层表面不宜过于干燥,若过干,应在施工前隔夜浇水湿润成阴干状,含水量也不易过大,否则会降低与基层墙体的粘结力,引起发空鼓、虚贴现象。
(4)粘贴CPC装饰保温板
将胶粘剂均匀抹于待贴的保温板表面,然后对准控制线将保温板贴于墙面并按压平实。采用点框法时应在CPC保温板四周涂抹50mm宽,10mm厚的胶粘剂,并在CPC保温板下侧预留宽度为30mm的透气通道,中间部位均匀分布涂抹直径为150mm,10mm厚的圆形粘接点(布点密度根据板的规格而定),采用条粘法时应在保温板内表面均匀涂抹6~8mm厚的胶粘剂并用专用疏板刮出横条状粘结带后,在CPC保温板中间位置纵向刮出宽度为50mm的透气通道。建筑高度在60m以下时应保证粘贴面积不低于保温板面积的40%。建筑高度在60m以上时,粘贴面积应不低于保温板面积的60%。
粘贴时,水平方向应由墙角及门窗处向两侧粘贴,粘贴时应轻揉、均匀挤压,并随时用2m靠尺和托线板检查平整度和垂直度。注意清除板边溢出的胶粘剂,相邻板间侧边不得有胶粘剂。板缝應尽量拼接严密,对板间存留较大缝隙的,宜切割保温板填塞缝口或采用泡沫聚氨酯填缝剂填缝。应严格控制相邻板块高差±1.5mm。
(4)涂抹抹面胶浆,铺贴耐碱网格布
在CPC保温板表面首遍涂1~2mm抹面胶浆,然后将耐碱网格布横向铺贴并压入胶浆中,接搓方式为上皮压下皮,抹面胶浆应充分包裹网格布,要平整压实、无褶皱。首遍抹面胶浆初凝至可以触碰时再抹第二遍抹面砂浆,厚度约为1.5mm,以完全覆盖且微见网格布轮廓为宜。抹面层厚度不宜大于5mm。抹面胶浆施工间歇处应留在阴角处或CPC板块接近中间位置,以方便后续施工的搭接。间距不小于100mm。建筑首层外墙墙体及易承受碰撞部位须首先增设一层网格布,网格布之间采用对接工艺,控制抹面层整体厚度为5~7mm。
(5)锚栓加固
在粘板后(时间根据胶粘剂凝速度)、根据单项工程设计要求钻孔,孔径视锚固件直径而定,然后用橡皮锤将专用锚栓敲入孔内拧紧压平于板面并不压破水泥基卷材面层为宜。专用锚栓布置密度为:饰面为涂料时,标高在20m以下的部位可不安装锚固件:20~60m宜为4~6个/m2;60m以上的锚栓分布宜为6~8个/m2。锚固件圆盘压住CPC保温板。
4施工注意事项
(1)CPC装饰保温系统工程施工期间以及完工24小时内,基层及环境空气温度不应低于5℃。夏季应避免阳光暴晒。在5级以上大风天气和雨天不得施工。严禁雨中施工,遇雨施工或雨季施工应有可靠的防雨措施。
(2)粘贴时应按顺砌方式粘贴,竖缝逐行错缝1/2板长粘贴,阴阳角应错茬搭接,并随时用2m靠尺和托线检查平整度和垂直度,用水平尺检查水平度。粘贴门窗洞口四周CPC保温板时应用整版保温板,拼缝不得位于门窗洞口的四角处,墙面边角处粘贴保温板时最小尺寸应不低于200mm。翻包时被压和翻包长度均不得不小于100mm。门窗洞口侧边应粘贴CPC保温板并做好收头处理。
(3)涂抹抹面胶浆前必须对保温板的平整度、垂直度和阴阳角方正度,以及门窗上口和下口的边沿线的水平度、门窗洞口的侧沿线垂直度进行检查,符合要求后方可进行抹面胶浆的施工。施工时切忌多次反复揉搓,以及造成脱浆形成空鼓、裂纹。
(4)分格缝施工时,分格条应在抹灰工序时就放入,待砂浆初凝后起出,修整缝边,分两次填嵌建筑密封膏,勾缝厚度约为缝宽的1/3。
5 质量验收
CPC装饰保温系统施工质量验收包括施工过程验收和竣工验收。施工过程验收由监理工程师组织相关验收;竣工验收有建设单位项目负责人组织专家组进行验收,工程质量监督机构对此实施监督。
(1)CPC装饰保温系统在施工过程中,应对基层墙面处理、保温层厚度和密封与锚固件处理进行隐蔽工程验收。
(2)CPC装饰保温系统工程使用的胶粘剂,抹面胶浆,增强网,锚固件的材质、规格、安装间距、数量及锚固件的拉拔力符合规程及单项工程设计要求。
(3)门窗洞口、阴阳角、分隔逢、变形缝等节点的施工安装应符合《CPC硬泡聚氨酯复合板外墙外保温系统(薄抹灰)建筑构造》图集。
(4)CPC装饰保温系统工程竣工后,有建设单位委托具有相应节能检测资质的单位进行传热系统现场抽样检测,提供检测报告。
6 结论
随着高层建筑如雨后春笋般的建设,建筑节能是执行国家节约能源、保护环境的基本国策,是缓解能源紧张,解决社会经济发展与能源供应不足这对矛盾的有效措施。高层建筑外墙外保温系统作为高层建筑节能的重要手段,必须引起重视。
参考文献
[1]JGJ26-95,民用建筑节能设计标准(采暖居住建筑部分) [S].北京:中国建筑工业出版社,1996.
[2]马保国.外墙外保温技术[M].北京:化学工业出版社,1999.32-53.
作者简介:王云波,出生年月:1979年7月17日,2001年毕业于石家庄铁道学院建筑工程专业,现工作于中铁十二局集团建筑安装工程有限公司,任副经理,工程师。
注:文章内所有公式及图表请用PDF形式查看。