污水进入污水气提塔后,由于污水气提塔填料的通过能力下降,对介质的阻力增大,污水不能及时从填料上部流下,在气提过程中有部分液体被N2、H2S、CO2气体带到下游,对下游克劳斯炉的使用造成极大的安全隐患,针对这一情况采取了蒸汽加热吹扫、碱液浸泡、溶硫剂浸泡等工作,但效果不明显。最终采取加装一套污水气提塔尾气分液装置,保证了下游克劳斯炉的正常运行
After the sewage enters the waste water stripping tower, the resistance to the medium increases due to the decrease of the passing capacity of the sewage stripping tower packing, and the sewage can not flow down from the upper part of the packing in time. In the stripping process, some of the liquid is N2, H2S and CO2 gas belts To the downstream, the use of downstream Klaus furnace caused great potential safety problems, in view of this situation has taken steam heating purge, soak lye, sulfur dissolving agent soaking work, but the effect is not obvious. The final take to install a set of sewage gas tower exhaust separation device to ensure the normal operation of the downstream Claus furnace