论文部分内容阅读
The system damping and dynamic characteristics can be further improved by properly increasing thedamping coefficient ξh. For a special hydraulic damping structure, an arciform damping clearance often used inFCS, a mathematical model has been established for fluid flow using the theory of laminar flow in the clearanceof parallel plates. Analytical calculations are made for fluid flow in the arciform clearance and relational expres-sion is deduced for flow rate along the arciform cleaance height, pressure difference, maximum arciform clear-ance height, the flow rate for the fluid flow in arciform clearance as well, and its simplified formula is obtainedby using the theory of hydrodynamics and the curve - fitting method. This paper consists of two sections: the firstsection focuses on the theoretical analysis by using the simplified mathematical model and the second sectionmainly describes experimental analysis. The simplified formula is corrected with experimental results by consid-erig various boundary conditions of the damping clearance. Experimental results show that this study of arciformdamping clearance is reliable and practical.