论文部分内容阅读
3 4 不同抗震等级框架的抗震计算3 4 1 一级框架(1)强柱弱梁 梁柱节点处除框架顶层和柱轴压比小于0 15者外,柱端组合的弯矩设计值应符合下式要求:ΣMc =1 4ΣMb (6 ) 9度和一级框架结构,尚应符合:ΣMc =1 2ΣMbua (7)式中 ΣMc———节点上下
3 4 Seismic Calculation of Different Seismic Rating Frames 3 4 1 Primary Frames (1) Beam-to-column joints of strong column and weak beam shall have the design values of bending moment of column-end combination except the top-layer and column- The following requirements: ΣMc = 1 4ΣMb (6) 9 degrees and a framework structure, should still meet: ΣMc = 1 2 Σ Mbua (7) where ΣMc --- node up and down